Filter Results By:

Products

Applications

Manufacturers

High Frequency

High Frequency operating at 3–30 MHz.


Showing results: 1051 - 1065 of 1264 items found.

  • PCI Express Receiver Board

    AD12-2000-IRIGB - Ultraview Corporation

    The AD12-2000-IRIGB is a high performance wideband 0.3-1.8GHz PCIe-bus receiver on a single PCIe Gen3 board, that can continuously digitize a wide portion of the RF spectrum, with a 3.6GSPS 12-bit A/D that can be synchronized with stability of better than +/- 100 picoseconds with respect to an IRIG-B 1PPS signal and global time codes from a satellite receiver or local site time reference. Designed for demanding military, scientific, industrial, communications, safety and electrical power utility applications, the AD12-2000-IRIGB has 60dB of gain adjust range (manual and AGC with programmable loop bandwidth), a wideband noise figure of 9dB, +11dBm 1dB compression point, and 2dB peak-to-peak ripple over the 300MHz to 1.6GB frequency spectrum.

  • Waveguide Electromechanical Relay Switches C, X, Ku, K & Ka Bands up to 40 GHz

    Fairview Microwave Inc.

    Waveguide Electromechanical Switch models cover C, X, Ku, K, Ka frequency bands up to 40 GHz. SPDT and Optional DPDT* Configurations with Latching Self Cut-Off Actuators, TTL Logic, and Position Indictors with manual override. Patented Motor Drive with Arc Suppression. Designs support WR-137, WR-112, WR-90, WR-75, WR-62, WR-42, and WR-28 waveguide sizes with O Rings for pressurized operation. Power handling capability up to 12 kW CW and 320 kW Peak. These waveguide electromechanical relay switches deliver desirable performance that includes high isolation levels up to 105 dB, and extremely low insertion loss down to 0.01 dB.

  • SDC-A Series Multi-Octave Downconverter

    SDC-A - Saluki Technology Inc.

    SDC-A Series Multi-Octave Downconverter belongs to our microwave upconverter series that has a high performance and an octave overage by RF signal. Its frequency step is precise and accurate to 10Hz with a variety of IF and signal bandwidth choices.This series of converters is mainly used for electronic countermeasure system, radar system, and satellite communication system. Its excellent phase noise, clutter suppression, and in-band flatness data can provide a transparent RF transmission channel to all videos or data communications. All programming commands can be set through a local panel or through network remotely. SDC-A series microwave downconverter is available in 2U/ 4U sizes.Applications: T&M Systems / Satellite Communications / MIMO / Radar System

  • SUC-A Series Multi-Octave Upconverter

    SUC-A - Saluki Technology Inc.

    SUC-A Series Multi-Octave Upconverter belongs to our microwave upconverter series that has a high performance and an octave overage by RF signal. Its frequency step is precise and accurate to 10Hz with a variety of IF and signal bandwidth choices.This series of converters is mainly used for electronic countermeasure system, radar system, and satellite communication system. Its excellent phase noise, clutter suppression, and in-band flatness data can provide a transparent RF transmission channel to all videos or data communications. All programming commands can be set through a local panel or through network remotely. SUC-A series microwave upconverter is available in 2U/ 4U sizes.Applications: T&M Systems / Satellite Communications / MIMO / Radar System

  • Combination Board Tester

    Qmax Test Technologies Pvt. Ltd.

    Combination Board Tester capable of testing highly complex and dense PCBs employing various test techniques on a single platform. It can perform Board Level Functional Test through edge connectors of a PCB, and guided probe diagnostics utility to reliably repair Digital/Analog and Mixed Signal PCBs of various complexities and conventional PCBs. An In –Circuit device test by configuring Pin Drivers to High Current Pin Driver mode and interface to the UUT either through Clips / Probes or nail bed and on board clock disable HW feature are the all time favorite . The in-built high frequency 14bit Analog Driver / sensors synchronized with digital drivers for covering analog / mixed signal devices with high degree of accuracy.

  • Universal PD & EMI analyzer

    Spark P3 - Manta Test Systems

    Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.

  • Login Digital Epstein Tester Model

    Model EP400 - Gopal Electronics

    Digital Epstein Tester EP-400 is designed to measure AC magnetic properties of flat rolled magnetic materials at high frequency by using Watt-meter, Ammeter, Voltmeter and Source. Epstein bridge test method is a fundamental method for evaluating the magnetic performance of flat-rolled magnetic materials in either sheared or stress relief annealed condition. This test method is suitable for design, specification acceptance, service evaluation, and research and development.

  • Balance Thermocouple Power Sensor, DC To 50 GHz

    N8487S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Balance Thermocouple Power Sensor, DC To 18 GHz

    N8481S - Keysight Technologies

    The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.

  • Precision Capacitance Meter

    TH2638C - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638 - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638B - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Precision Capacitance Meter

    TH2638A - Changzhou Tonghui Electronic Co., Ltd.

    TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.

  • Preamplifiers

    Com-Power Corporation

    Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.

  • DC High-Voltage Test Device

    PGK 80 - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

Get Help